<?xml version="1.0" encoding="UTF-8"?>
<!-- GXML Toolbox V3.3 R20220330;  http://www.gaeb-toolbox.de/  -->
<GAEB xmlns="http://www.gaeb.de/GAEB_DA_XML/DA83/3.3"><GAEBInfo><Version>3.3</Version><VersDate>2021-05</VersDate><Date>2026-08-24</Date><Time>20:00:59</Time><ProgSystem>/ GXML Toolbox V3.3 R20220330</ProgSystem><ProgName>ORCA AVA 27 27.00.00</ProgName><Certific>Available</Certific></GAEBInfo><PrjInfo><NamePrj>230801</NamePrj><LblPrj>Feuerwehrgerätehaus Hördt</LblPrj><Cur>EUR</Cur><CurLbl>Euro</CurLbl></PrjInfo><Award><DP>83</DP><AwardInfo><Cur>EUR</Cur><CurLbl>Euro</CurLbl><CnstEnd>2026-11-15</CnstEnd></AwardInfo><AddText><OutlineAddText><span>1. Angaben zur Baustelle</span></OutlineAddText><DetailAddText><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;font-weight:bold;"><span style="font-family:Arial;font-size:10pt;">1. Angaben zur Baustelle</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Baustelle befindet sich in Hördt am Friedhof, erreichbar</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">über die L493 von Rülzheim kommend, über die L552 von</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Kuhardt kommend oder durch die Ortsgemeinde Hördt</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">kommend.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Nördlich der Baustelle befindet sich in unmittelbarer Nähe der</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Friedhof und in einer Entfernung von circa 150 m der Kath.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Kindergarten. Östlich der Baustelle befindet sich in circa 75 m</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Entfernung ein Wohngebiet.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Es wird ein Feuerwehrgerätehaus errichtet.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Flächen für die Baustelleneinrichtung gemäß</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Baustelleneinrichtungsplan und in Absprache mit der</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Bauleitung.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;font-weight:bold;"><span style="font-family:Arial;font-size:10pt;">2. Bauliche Anlage</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Funktion:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Der Neubau wird als Feuerwehrgerätehaus mit drei Stellplätzen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">und Nebenräumen errichtet.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Erschließung des Gebäudes erfolgt über eine neu zu</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">errichtende Straße.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Das Gebäude ist nicht unterkellert und hat die Abmessungen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">25,74 m x 16,49 m.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;text-decoration:underline ;"><span style="font-family:Arial;font-size:10pt;">Beschreibung der Bauteile:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Fahrzeughalle wird eingeschossig in Stahlbetonbauweise</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">mit einem Pultdach errichtet. Die Nebenräume werden</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">zweigeschossig in Massivbauweise mit Stahlbetondecken und</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">einem Pultdach errichtet. Dazwischen befindet sich ein</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">zweigeschossiger Flachdachbau in Massivbauweise, der unter</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">anderem die Technik und Lagerräume beinhaltet.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;text-decoration:underline ;"><span style="font-family:Arial;font-size:10pt;">Dach:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Dächer bestehen aus Aluminium Profilbahnen bzw.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Thermodach mit Photovoltaik. Auf dem Flachdach stehen die</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Wärmepumpe und der Kompressor sowie weitere Technik.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;text-decoration:underline ;"><span style="font-family:Arial;font-size:10pt;">Außenwände:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Außenwände werden als tragende Stahlbetonwände bzw.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">KS Mauerwerk hergestellt. Außenseitig wird die Fassade mit 22</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">cm Mineralwolle gedämmt.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;text-decoration:underline ;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;text-decoration:underline ;"><span style="font-family:Arial;font-size:10pt;">Gründung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Gründung des Neubaus erfolgt über eine tragende</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Bodenplatte in WU - Beton, die mit Dämmplatten unterlegt ist.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Umlaufend befindet sich eine Frostschürze.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;text-decoration:underline ;"><span style="font-family:Arial;font-size:10pt;">Fassade:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Fassade besteht aus einem 22 cm WDVS - System aus</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Mineralwolle mit Armierungsgewebe, Kleber und Oberputz.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;font-weight:bold;"><span style="font-family:Arial;font-size:10pt;">3. Benutzung des öffentlichen Straßenraumes und Öffentlicher Freiflächen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Das Baugelände befindet sich neben dem Friedhof in Hördt.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die zur Verfügung stehende Baufläche wird begrenzt durch:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Im Norden durch den Friedhof</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Im Westen durch den Parkplatz</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Im Süden durch die L493 bzw einen Grünstreifen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Im Osten durch die Stoppelstraße</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Das Gelände ist zum Zeitpunkt der anstehenden Arbeiten</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">weitgehend eben.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Der Bieter hat sich vor Angebotsabgabe in ausreichendem</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Umfang von der örtlichen Situation und den damit</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">zusammenhängenden preisbildenden Faktoren ein Bild zu</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">verschaffen. Hierzu gehören auch die Möglichkeiten der Anund</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Abfahrt.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Es ist darauf zu achten, dass der Betrieb des Kindergartens und</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">des Friedhofs während der Baumaßnahme weitgehend</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">ungestört stattfinden kann. Auf Anordnung des AG sind die</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">lärmintensiven Arbeiten bei einer Beerdigung zu unterbrechen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">(Dauer ca. 30 - 60 Min.).</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Daher sind betriebsbedingte Unterbrechungen und Stillstand der</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">lärmintensiven Arbeiten, sowie erhöhte Anforderungen an</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Sicherungs-, Transport- und Aufräummaßnahmen im</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Pauschalpreis einzukalkulieren.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Regelarbeitszeiten sind von 7 - 18 Uhr. Samstagsarbeit ist</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">möglich und nicht anmeldepflichtig.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Ferner ist zu beachten und zu gewährleisten, dass diverse</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Arbeiten auch außerhalb der normalen Tagesarbeitszeit bzw. an</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">den Wochenenden oder Feiertagen - jeweils nach Anweisung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">der Bauleitung in zeitnaher Absprache mit dem AN - zu leisten</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">sind. Samstagsarbeit oder Überstunden werden nicht gesondert</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">vergütet, wenn sie zur Erfüllung seiner vertraglichen Leistung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">erforderlich werden. Mehr- und Wochenendarbeit sind mit dem</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Auftraggeber jedoch abzustimmen und bei den entsprechenden</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Behörden anzumelden.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;font-weight:bold;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;font-weight:bold;"><span style="font-family:Arial;font-size:10pt;">4. Angaben zur Ausführung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;text-decoration:underline ;"><span style="font-family:Arial;font-size:10pt;">Baustelleneinrichtung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Der Bauzaun wird bauseits errichtet. Der Bauzaun ist ständig</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">geschlossen zu halten. Änderungen am Bauzaun dürfen nur</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">nach Absprache mit der Bauleitung vorgenommen werden.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Eine mögliche Mitbenutzung der Flächen außerhalb des</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Bauzauns sind vom Bieter rechtzeitig mit der Bauleitung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">abzustimmen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Ein Baustellen WC, Bauwasser und Baustrom werden zur</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Verfügung gestellt (die Verbräuche werden umgelegt).</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die allgemeine Baustellenbeleuchtung wird bauseits</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">eingerichtet, die Arbeitsbeleuchtung wird nicht gestellt. Zudem</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">wird eine Bauleistungsversicherung bauseits abgeschlossen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">(Umlage wird vorgenommen).</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Der Baustelleneinrichtungsplan ist mit der Bauleitung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">abzustimmen und unmittelbar nach Abschluss einzelner</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Leistungen auf ein unbedingt notwendiges Maß zu reduzieren.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Es wird dem Bieter empfohlen, sich vor Ort über die</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Gegebenheiten zu informieren.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;text-decoration:underline ;"><span style="font-family:Arial;font-size:10pt;">Sicherungsmaßnahmen:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Wege für den Personen- bzw. Fahrzeugverkehr auf der</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Baustelle dürfen nicht durch Bauarbeiten beeinträchtigt werden.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Zufahrtswege für Feuerwehr-, Rettungs-,Polizei- und sonstige</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Hilfsfahrzeuge sind stets freizuhalten.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;text-decoration:underline ;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;text-decoration:underline ;"><span style="font-family:Arial;font-size:10pt;">Gerüste:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Das Gerüst wird entlang der Außenwände mit einer</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Belastungsklasse 3 errichtet.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;font-weight:bold;"><span style="font-family:Arial;font-size:10pt;">5. Ergänzende Hinweise</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;text-decoration:underline ;"><span style="font-family:Arial;font-size:10pt;">Bauschutt:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Eigener Bauschutt und Abfall ist arbeitstäglich, fachgerecht zu</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">entsorgen. Wird der Schutt und Müll nicht entsorgt, so wird</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">dieser auf Kosten des AN beseitigt. Ein entsprechender Teil (bis</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">5%) der Brutto - Abrechnungssumme wird als Umlage in den</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Abschlagszahlungen einbehalten.</span></p></DetailAddText></AddText><AddText><OutlineAddText><span>ZTV Elektro</span></OutlineAddText><DetailAddText><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Diese zusätzlichen technischen Vorschriften gelten  für elektrische Kabel- und Leitungsanlagen in Gebäuden ( DIN 18 382 ), Blitzschutzanlagen ( DIN 18 384 ), Gebäudeautomation ( DIN 18386 ) Brandmeldeanlagen ( DIN 14675 ) elektrische Kabel- und Leitungsanlagen außerhalb von Gebäuden, sowie alle Montagen einschließlich Lieferungen von elektrischen Stark- und Schwachstromanlagen ( VOB/VOL ).</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Sie werden Vertragsbestandteil nach Maßgabe der Rangfolge, wie sie in den Besonderen Vertragsbedingungen genannt ist.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1. Eingeführte technische Vorschriften 1.1. Verbandsvorschriften und TAB</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Anlage ist nach den Regeln der Technik, im besonderen nach den gültigen VDE - Vorschriften, im wesentlichen 0100, 0105, 0108-100, 0113; 0171, 0190, 0800, 0833; DIN 18014; DIN 18015; DIN EN 50173; DIN EN 50174 LAR - Leitungen, Richtlinie (Rheinland-Pfalz) über Brandschutztechnische Anforderungen an Leistungsanlagen sowie den besonderen Vorschriften in den jeweils gültigen Fassungen der TAB des Energiieversorgungsunternehmens,  den Allgemeinen Feuerversicherungs-Bedingungen ( AFS ), den Bedingungen der Schadenversicherer (VDS) und nach den Richtlinien der VDEW auszuführen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Zusätzlich sind die Unfallverhütungsvorschriften (UVV), Niederspannungsrichtlinie, Niederspannungsanschlussverordnung, Betriebssicherheitsverordnung, Gerätesicherheitsverordnung und EMV- Richtlinie sowie die Aufschaltbedingungen der Feuerwehr für Brandmeldeanlagen einzuhalten.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1.2. Spezielle Vorschriften</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Anlage ist mit den Installationsplänen entsprechend DIN 40719 - 11, DIN EN 60848, DIN EN 61082, DIN EN 61355, DIN EN 62027; DIN EN 62079 zu dokumentieren. Installationspläne sind im Dateiformat DWG / ACAD 2000 unter Einhaltung vorgegebener Layer zu erstellen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Schaltungsunterlagen für Verteiler sind nach DIN 40719 - 11, DIN EN 60848, DIN EN 61082, DIN EN 61355, DIN EN 62027; DIN EN 62079 zu dokumentieren.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Verteilerpläne, Stromlaufpläne, Klemmenpläne, Bestückungsliste sind im Dateiformat Proplan, in der jeweils aktuellen Version zu erstellen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Dem Auftragnehmer werden Leistungsverzeichnis und Pläne im Dateiformat PDF, DWG, EMH, zur Verfügung gestellt.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Revisionspläne sind grundsätzlich in den Formaten, DWG, Verteilerpläne in *.emh zu erstellen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1.3. Geltungsdatum</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Allgemeinen Technischen Vorschriften ATV - VOB / C und die weiteren in Nr. 1.1. und den Verbindungsunterlagen genannten Normen gelten in der drei Monaten vor Ablauf der Angebotsfrist gültigen Fassung, wie sie im Bundesanzeiger bekannt gemacht bzw. bei den weiteren DIN - Normen angezeigt worden ist.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">2. Stoffe , Bauteile </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">2.1. Allgemeines</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Qualität der vorgesehenen Materialien ist durch Hersteller und Typenangabe nachzuweisen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Musterstücke - besonders von Leuchten - sind vor Bestellung der Bauleitung unaufgefordert vorzulegen. Die Bauleitung entscheidet über die zur Verwendung kommenden Fabrikate und Typen und deren Anzahl.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">2.2. Schalter und Steckdosenausführung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Schalter sind, sofern im LV nicht anderes angeben, als Wippenschalter mit weißer Wippe, weißer quadratischer Abdeckplatte, aus Thermoplast zu liefern. Gleiche Ausführung gilt auch für die Steckdosen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">siehe auch Vortext Installationsarbeiten</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">2.3 Leuchten</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Leuchten müssen der Raumnutzung entsprechen, welche nach DIN EN 12464, DIN 5035 die erforderliche Beleuchtungsqualität sicherstellen und zum Nachweis der Sicherheit das VDE-Zeichen tragen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">2.5 Rohrschellen, Befestigungsschrauben</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Rohrschellen sind in kräftiger Ausführung, Befestigungsschrauben in nicht rostender Ausführung zu wählen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">2.67 Schlösser</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 1 ) Für sämtliche Verteiler sind Einheitsschlösser,  Schließanlage mittels Halbzylinder des Auftraggebers vorzusehen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Bei Kabelverteiler im Außenbereich bzw. Trafostationen ist ebenso die Schließanlage mittels Halbzylinder des Auftraggebers vorzusehen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Für schlüsselbetätigte Taster/Schalter ist die Schließung KMS1 einzubauen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">(Halbzylinder der Schließanlage sind beim Auftraggeber erhältlich) .</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 2 ) Für Trafostationen sind sämtliche Türen mit Panikschlössern für Doppelschließung passend für beigestellte Zylinder nach (Schließplan des Auftraggebers) auszuführen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">3. Ausführung </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">3.1. Allgemeines</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 1 ) die Elektroinstallation beginnt ab Hausanschluss, Verteilerabgang bzw. bei Mittelspannungsanlagen ab Übergabeschalter und umfasst die gesamte betriebsfertige Anlage einschließlich des Brandschutzes.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 2 ) Jede sich unter Umständen während der Ausführung ergebende Änderung bedarf der ausdrücklichen Zustimmung des Fachingenieurs der Bauleitung.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 3 ) Bei Beginn der Rohbauarbeiten überprüft der Auftragnehmer die vorgesehenen Aussparungen und Durchbrüche und legt diese gemeinsam mit dem zuständigen Fachingenieur der Bauleitung verbindlich fest.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 4 ) Vor Montagebeginn ist die gesamte Installation, insbesondere Verteilerplätze und Leitungsführung, mit dem Bauleiter festzulegen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 5 ) Transport zur Verwendungsstelle und die Lagerung erfolgt auf Gefahr des Unternehmers.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">3.2. Drei- bzw. Fünfleitersystem</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 1 ) Die elektrische Anlage ist als TN - S - System, in 3 - bzw. 5 -Leitersystem auszuführen, wobei der Schutzleiter  in seiner Gesamtlänge gelbgrün gekennzeichnet ist. N- und PE-Leiter sind in der gesamten Anlage getrennt zu führen und werden erst am Hauptverteiler (ZEP) verbunden.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 2 ) Arbeitsstromkreise und Steuerstromkreise sind farbig nach VDE 0293, u. 0113 zu verdrahten.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">3.3. Verteiler</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 1 ) Die Verteiler sind mit Reihenklemmen, für N (Neutralleiter) mit Reihentrennklemmen und PE (Schutzleiter) Klemmen auszulegen. Bei jedem Stromkreis muss eine Isolationsprüfung ohne Abklemmen der N-Leiter von den einzelnen Klemmen möglich sein. Als Leistungsschutz sind Leistungsschutz-Automaten Typ B bzw. C einzubauen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 2 ) Abdeckungen müssen einfach abnehmbar sein ( ohne Demontage von Schraubkappen usw. ). An geeigneter Stelle des Verteilers ist eine Plantasche vorzusehen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 3 ) Die vom Auftraggeber genannten Stromstärken für Luftschütze gelten für eine Belastung nach AC 3 ( Kurzschlußläufermotor ).</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Vor Anfertigung der Verteiler sind die Ausführungszeichnungen der Bauleitung zur Prüfung und Einwilligung vorzulegen, sofern keine anderen Angaben erfolgen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Verteilerpläne und Stromlaufpläne sind im Dateiformat *.emh, in der jeweils aktuellen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Version zur Verfügung zu stellen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">3.4. Leitungen u. Kabel</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 1 ) Alle Leitungen und Kabel dürfen nur horizontal und vertikal verlegt werden. Die Leitungen in Decken oder Böden müssen rechtwinklig zur Wand verlaufen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 2 ) Bei Rohrverlegung unter Putz sind bei normalem Mauerwerk die Schlitze zu fräsen. Beträgt die Länge der Rohrleitung mehr als 30 m oder sind mehr als 3 Bogen vorhanden, werden Zugkästen eingebaut.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 3 ) Bei Verlegung von Leitungen oder Kabel auf Abstandsschellen darf ein maximaler Abstand der Befestigungsschellen von 0,30 m nicht überschritten werden.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Bis zu 2 Leitungen können auf Iso-Abstandschellen, mehr als 2 Leitungen sind in Installationsrohr mittels Schellen bzw. in Installationskanal oder Hängeschellen, Kabelrinnen unter Beachtung der max. Belastung verlegt werden.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Leitungen und Kabel bei Deckendurchführungen sind mittels Schutzrohr zu schützen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Bei der Installation von Leitungsanlagen in Baulichen Anlagen für Menschenansammlungen ist die DIN VDE 0100-718 in der jeweils neuesten Fassung zu berücksichtigen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 4 ) Bei paralleler Leitungsführung mit fernmeldetechnischen Kabeln und Leitungen ist der nach VDE 0800 vorgeschriebene Abstand einzuhalten oder es ist ein Trennsteg erforderlich.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 5 ) Abstandsbügel, Registerschienen und Kabelbahnen oder Kanäle müssen solide und reichlich bemessen sein., so daß Erweiterungen jederzeit möglich sind. Der Abstand von Bügel zu Bügel darf in keinem Fall 0,70 m überschreiten.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 6 ) Auf Brandschutz und Brandlasten in Flucht-und Rettungswegen ist insbesondere zu achten und die LAR einzuhalten.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">3.5. Apparaturen, Geräte</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Anbringung und Befestigung von Apparaturen und Geräten ist gemeinsam mit der Bauleitung festzulegen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">3.6. DV- Inhousnetze</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Diese sind entsprechend der DIN EN 50173; DINEN 50174 sowie unter Beachtung der Spezifikationen des Fachbereich Informationstechnik zu installieren.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">3.7. Brandschutz</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Der gesamte Brandschutz von Kabel- und Leitungsanlagensowie Verteiler ist Richtlinienkonform auszuführen. Die gesamten Einbauten sind im Installationsplan numerisch einzutragen und in einer beigefügten Liste sind die eingebauten Produkte zu beschreiben sowie die Herstellerspezifischen Unterlagen  (Übereinstimmungserklärung) hinzuzufügen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">3.8. Einweisung des Bedienungspersonals</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 1 ) Das Bedienungspersonal und die Bauleitung sind über die Eigenart und Wartung der Anlage eingehend mündlich und schriftlich zu unterrichten.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 2 ) Wartungs- und Bedienungsanweisungen sind dem Auftraggebert vor Abnahme, in deutscher Schriftform, vierfach auszuhändigen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">4. Nebenleistungen </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Folgende Leistungen sind Nebenleistungen entsprechend VOB / C DIN 18 382 Nr. 4.2, Wenn sie nicht durch besondere Ansätze in der Leistungsbeschreibung erfaßt sind :</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 1 ) Liefern und Montieren von Zubehör, die für eine betriebsfertige Anlage- Herstellung und / oder nach den einschlägigen Vorschriften aller im Leistungsverzeichnis aufgeführten Positionen erforderlich sind,</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 2 ) Herstellen der erforderlichen Schalt- und Detailpläne, sofern sie nicht von der Stadt geliefert werden,</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 3 ) Einweisen des Bedienungspersonals entsprechend Nr. 3.8.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 4 ) Anfertigen von Bestandszeichnungen und des Abnahmeberichtes entsprechend Nr. 5.2.,</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 5 ) Anfertigen und Anbringen des</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Gesamtschaltbildes sowie der Verteilerbeschriftung entsprechend Nr. 3.7..</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">5. Abrechnung </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">5.1. Aufmass</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">das Aufmass erfolgt gemeinsam im Zuge der Montage entsprechend dem Leistungsverzeichnis unterteilt in Bauabschnitte und Räume.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">5.2. Bestandszeichnungen, Dokumentation und Abnahmeberichte</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 1 ) Der Auftragnehmer hat zur Abnahme der Arbeiten die normgerechte Dokumentation in Form von Papier Originalen ( Installationspläne, Verteilerpläne sowie Übersichtsschemata der einzelnen Anlagen ) 3-fach, sowie in den vorgenannten Dateiformaten (PDF und DWG) zur Verfügung zu stellen. </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 2 ) Zur selben Zeit ist der Abnahmebericht Errichterbescheinigung, Prüfprotokoll nach VDE 0100-600 für alle gemessenen Werte erforderlich ebenso Konformitätserklärungen für alle Verteiler, Schaltanlagen, Brandabschottungen und Funktionserhaltseinrichtungen zu übergeben. Ebenso die Abnahmeprotokolle erforderlicher Sachverständigenabnahmen, und Herstellerabnahmen zu übergeben.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 3 ) Der Auftragnehmer hat mit den Bestandszeichnungen eine detaillierte Stückliste unter Angabe der Fabrikate, Typenbezeichnungen und Leistungsdaten der gelieferten Geräte und Betriebsmittel</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( insbesondere Leuchten, Lampen, Motoren und Transformatorstation ) zu erstellen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 4 ) Für elektrische Anlagen von Versammlungsstätten, Aufzugsanlagen, EX - Anlagen sowie von Brandmeldeanlagen sind Abnahmeberichte vorzulegen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">( 5 ) Für Antennenanlagen sind Messprotokolle gemäß Postvorschrift anzufertigen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">5.3. Betriebsprüfung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Der endgültigen Abnahme hat eine vom Auftragnehmer durchzuführende Betriebsprüfung voranzugehen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">5.4. Messung der Phasenbelastung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die gleichmäßige Belastung der vorhandenen Aussenleiter L1 - L3 ist durch Messung festzustellen und protokollarisch festzuhalten. Ebenso die Messwerte der N- und PE - Leiter Strombelastung .</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">5.5. Messung und Prüfung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:482pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Prüfung der elektrischen Anlage ist nach DIN/VDE 0100 Teil 600 durchzuführen alle Messwerte sind zu dokumentieren. Die Ergebnisse der Prüfung sind in einer Bewertung festzuhalten. Für Fernmeldeanlagen ist VDE 0833 - 1 anzuwenden.</span></p></DetailAddText></AddText><BoQ ID="id605"><BoQInfo><Name>05</Name><LblBoQ>Baustelleeinrichtung Elektrotechnik und Baustellenbeleuchtun</LblBoQ><OutlCompl>AllTxt</OutlCompl><BoQBkdn><Type>BoQLevel</Type><LblBoQBkdn>Titel</LblBoQBkdn><Length>2</Length><Num>Yes</Num></BoQBkdn><BoQBkdn><Type>BoQLevel</Type><LblBoQBkdn>Bereich</LblBoQBkdn><Length>2</Length><Num>Yes</Num></BoQBkdn><BoQBkdn><Type>BoQLevel</Type><LblBoQBkdn>Abschnitt</LblBoQBkdn><Length>2</Length><Num>Yes</Num></BoQBkdn><BoQBkdn><Type>Item</Type><Length>4</Length><Num>Yes</Num></BoQBkdn><BoQBkdn><Type>Index</Type><Length>1</Length><Num>No</Num></BoQBkdn><NoUPComps>4</NoUPComps><LblUPComp1 Type="Wages">Lohn</LblUPComp1><LblUPComp2 Type="Materials">Material</LblUPComp2><LblUPComp3 Type="Plant">Gerät</LblUPComp3><LblUPComp4 Type="Miscellaneous">Sonstiges</LblUPComp4><LblTime>Stunden</LblTime></BoQInfo><BoQBody><BoQCtgy ID="id608" RNoPart="01"><LblTx><p><span>Baustelleneinrichtung und Baustellenbeleuchtung</span></p></LblTx><BoQBody><BoQCtgy ID="id609" RNoPart="01"><LblTx><p><span>Baustellenversorgung und Baustellenbeleuchtzung Verteiler und Kabel</span></p></LblTx><BoQBody><BoQCtgy ID="id610" RNoPart="01"><LblTx><p><span>Baustellenversorgung, Verteilung und Kabel</span></p></LblTx><BoQBody><Itemlist><Remark ID="id611"><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Es wird die komplette Baustellenversorgung während der Bauzeit ausgeschrieben.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Baustellenversorgung ist entsprechend dem Baufortschritt aufzubauen und zu warten.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">A250 Hauptverteiler - Zählerverteiler mit Wandlermessung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">GV400 Gruppenverteiler (Anschluß Kran, V100, Container)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">V100 Hauptverteiler</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">EV63</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Bei allen Preisen ist eine einmalige Versetzung der Verteiler mit ein zu kalkulieren.</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="margin-top:0pt;margin-bottom:0pt;width:405pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Es wird die komplette Baustellenversorgung während der Bauzeit ausgeschrieben.</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Remark><Item ID="id612" RNoPart="1"><Qty>56.000</Qty><QU>Wo</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">A 400 - Zähler-/Wandlerschrank</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Anschlußleistung: 277kVA</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">nach IEC/EN 60439-4/A1+A2 (DIN/VDE 0660 T501/A1+A2) und DIN/VDE 43868/1-4</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Ausführung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Gehäuse (E49) aus elektrolytisch-verzinktem Stahlblech mit schwermetallfreier Kunststoff-Lackierung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Farbe: RAL 3001 -signalrot - mit Kranösen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">mit Doppeltür und 3-Punkt Stangenschloss</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">mit Drehknauf und Vorrichtung für Vorhangschloss inkl. feuerverzinktem Untergestell mit Ösen für Erdnägel</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Einbauten schutzisoliert</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Schutzart : IP 44</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Messeinrichtung Schutzart : IP 54</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Bestückung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 NH 3-Sicherungslasttrennschalter mit Sicherungen 500 A  mit Bolzenanschluss M10</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 NH 2-Lasttrennschalter mit Sicherungen 400 A mit Bolzenanschluss M10</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 NH 1-Sicherungslasttrennschalter 250 A mit Sicherungen, mit Bolzenanschluss M10</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">2 NH00-Sicherungslasttrennschalter 100 A mit Sicherungen, mit Bolzenabgang M8</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 Spannungspfadsicherung 3pol. 6 A - DIAZED-</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">3 DS-Zählerplätze ohne Zähler nach DIN 43870/2 für Zählerwechseltafel Quer- oder Hochformat</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 Wandleraufnahmevorrichtung mit CU - Schienen und ISO - Stützern vorverdrahtet für Einzelwandler</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">liefern, aufstellen und abbauen sowie anschliessen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">incl. Anmeldung Zähler beim zuständigen EVU</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Einbau der Wandler incl. Abholung beim zuständigen EVU</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">liefern, aufstellen und abbauen sowie anschliessen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Mietpreis pro Woche</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">angesetzte Mietdauer 56</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;"> Wochen</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:481pt;margin-top:0pt;margin-bottom:0pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">A 250 - Zähler-/Wandlerschrank</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id613" RNoPart="2"><Qty>56.000</Qty><QU>Wo</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">GV 400 - Gruppenverteilerschrank</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Anschlussleistung: 277kVA</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">nach IEC/EN 60439-4/A1+A2 (DIN/VDE 0660 T501/A1+A2)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Ausführung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Gehäuse (E30) aus elektrolytisch-verzinktem Stahlblech mit schwermetallfreier Kunststoff-Lackierung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Farbe: RAL 3001 -signalrot - mit Kranösen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">mit Doppeltür und 3-Punkt Stangenschloss</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">mit Drehknauf und Vorrichtung für Vorhängeschloss inkl. feuerverzinktem Untergestell mit Ösen für Erdnägel</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Einbauten schutzisoliert</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Schutzart : IP 44</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Bestückung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 NH 2-Lasttrennschalter mit Sicherungen 400 A mit Bolzenanschluss M10</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 CU-Sammelschienensystem 400 A</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 NH 2-Sicherungslasttrennschalter 355 A mit Sicherungen mit Bolzenanschluss M10</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 NH 1-Sicherungslasttrennschalter 250 A mit Sicherungen mit Bolzenanschluss M10</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">2 NH00-Sicherungslasttrennschalter 100 A mit Sicherungen mit Bolzenanschluss M8</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">2 NH00-Sicherungslasttrennschalter 100 A mit Sicherungen mit Bolzenabgang M8</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">liefern, aufstellen und abbauen sowie anschliessen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Mietpreis pro Woche</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">angesetzte Mietdauer 56 Wochen</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:481pt;margin-top:0pt;margin-bottom:0pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">GV 400 - Gruppenverteilerschrank</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id614" RNoPart="3"><Qty>56.000</Qty><QU>Wo</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">V 100 - Hauptverteilerschrank</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;"> Anschlussleistung: 87kVA</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">nach IEC/EN 60439-4/A1+A2 (DIN/VDE 0660 T501/A1+A2)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Ausführung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Gehäuse (E22) aus elektrolytisch-verzinktem Stahlblech mit schwermetallfreier Kunststoff-Lackierung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Farbe: RAL 3001 -signalrot - mit Kranösen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">mit Einfachtür und Fallriegel für Vorhängeschloss inkl. feuerverzinktem Untergestell mit Ösen für Erdnägel</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Einbauten bis einschließlich FI-Schutzschalter schutzisoliert</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Schutzart : IP 44</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Bestückung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 NH 1-Lasttrennschalter mit Sicherungen 125 A mit Bolzenanschluss M10</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 NH00-Sicherungsunterteil mit Sicherung 100 A</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 FI-Schutzschalter 4pol. 63 A/500 mA Typ B</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 CEE-Steckdose 5/63 A 400 V/6 h mit Leitungsschutzschalter 3/63 A -C-</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 FI-Schutzschalter 4pol. 63 A/30 mA Typ B</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">2 CEE-Steckdosen 5/32 A 400 V/6 h mit je 1 Leitungsschutzschalter 3/32 A -C-</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 NH 00-Sicherungsunterteil mit Sicherung 100 A</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 FI-Schutzschalter 4pol. 63 A/30 mA Typ B</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 CEE-Steckdose 5/32 A 400 V/6h mit Leitungsschutzschalter 3/32 A -C-</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">2 CEE-Steckdosen 5/16 A 400 V/6 h mit je 1 Leitungsschutzschalter 3/16 A -C-</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 FI-Schutzschalter 4pol. 63 A/30 mA Typ B</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">6 Schutzkontaktsteckdosen 2/16 A 230 V mit je 1 Leitungsschutzschalter 1/16 A -C-</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">liefern, aufstellen und abbauen sowie anschliessen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Mietpreis pro Woche</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">angesetzte Mietdauer 56 Wochen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">3 Schränke a 56 Wochen = 168 Wochen</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:481pt;margin-top:0pt;margin-bottom:0pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">V 100 - Hauptverteilerschrank</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id615" RNoPart="4"><Qty>56.000</Qty><QU>Wo</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">EV 63 - Endverteilerschrank</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Anschlussleistung: 44kVA</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Anschuß über Verlängerungskabel mit Stecker und Kupplung CEE 5x63A</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">nach IEC/EN 60439-4/A1+A2 (DIN/VDE 0660 T501/A1+A2)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Ausführung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Gehäuse (E06) aus elektrolytisch-verzinktem Stahlblech</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">mit schwermetallfreier Kunststoff-Lackierung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Farbe: RAL 3001 -signalrot - mit Kranösen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">mit Einfachtür und Fallriegel für Vorhängeschloss inkl. feuerverzinktem Untergestell mit Ösen für Erdnägel</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Einbauten bis einschließlich FI-Schutzschalter schutzisoliert</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Schutzart : IP 44</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Bestückung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 CEE-Gerätestecker 5/63 A 400 V/6 h</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 CEE-Steckdose 5/63 A 400 V/6 h für Kabelschleife</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 FI-Schutzschalter 4pol. 63 A/30 mA Typ B</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">2 CEE-Steckdosen 5/32 A 400 V/6 h mit je 1 Leitungsschutzschalter 3/32 A -C-</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">2 CEE-Steckdosen 5/16 A 400 V/6 h mit je 1 Leitungsschutzschalter 3/16 A -C-</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 FI-Schutzschalter 4pol. 40 A/30 mA Typ B</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">6 Schutzkontaktsteckdosen 2/16 A 230 V mit je 1 Leitungsschutzschalter 1/16 A -C-</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">liefern, aufstellen und abbauen sowie anschliessen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Mietpreis pro Woche</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">angesetzte Mietdauer 56 Wochen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:481pt;margin-top:0pt;margin-bottom:0pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">EV 63 - Endverteilerschrank</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id616" RNoPart="5"><Qty>56.000</Qty><QU>Wo</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">NSSHöu-J 3G95/50 mm²</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Schwere Gummischlauchleitungen für hohe mechanische Beanspruchungen entsprechend</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">DIN-VDE 0250, Teil 812.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Eigenschaften und Verwendung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Für den Anschluss von beweglichenGeräten und Maschinen bei sehr hohen mechanischen Beanspruhungen in trockenen und feuchten Räumen, im Freien und in explosionsgefährdeten Bereichen, besonders im Bergbau, in der Industrie, in Steinbrüchen und auf Baustellen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Leitungen dürfen fest verlegt werden z.B. in privisorischen Bauten oder auf Baustellen sowie an Förderanlagen und Maschinen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Technische Daten:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Uo/U: 0,6/1 kV</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Mantelfarbe: gelb</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Zuläsige Temparatur an der Leitungsoberfläche</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">bei fester Verlegung: -40° C bis +80° C</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">bei beweglichem Einsatz: -25° C bis +80° C</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Kleinster zulässiger Biegeradius</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">bei fester Verlegung: 4D (Durchmesser)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">bei beweglichem Einsatz: 5D (Durchmesser)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">liefern, verlegen und abbauen sowie anschliessen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Mietpreis pro Woche</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">angesetzte Mietdauer 56 Wochen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Länge 10 m</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:481pt;margin-top:0pt;margin-bottom:0pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">NSSHöu-J 3G95/50 mm²</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id617" RNoPart="6"><Qty>56.000</Qty><QU>Wo</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">NSSHöu-J 3G95/50 mm²</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Schwere Gummischlauchleitungen für hohe mechanische Beanspruchungen entsprechend</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">DIN-VDE 0250, Teil 812.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Eigenschaften und Verwendung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Für den Anschluss von beweglichenGeräten und Maschinen bei sehr hohen mechanischen Beanspruhungen in trockenen und feuchten Räumen, im Freien und in explosionsgefährdeten Bereichen, besonders im Bergbau, in der Industrie, in Steinbrüchen und auf Baustellen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Leitungen dürfen fest verlegt werden z.B. in privisorischen Bauten oder auf Baustellen sowie an Förderanlagen und Maschinen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Technische Daten:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Uo/U: 0,6/1 kV</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Mantelfarbe: gelb</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Zuläsige Temparatur an der Leitungsoberfläche</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">bei fester Verlegung: -40° C bis +80° C</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">bei beweglichem Einsatz: -25° C bis +80° C</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Kleinster zulässiger Biegeradius</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">bei fester Verlegung: 4D (Durchmesser)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">bei beweglichem Einsatz: 5D (Durchmesser)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">liefern, verlegen und abbauen sowie anschliessen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Mietpreis pro Woche</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">angesetzte Mietdauer 56 Wochen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Länge 40 m</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:481pt;margin-top:0pt;margin-bottom:0pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">NSSHöu-J 3G95/50 mm²</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id618" RNoPart="7"><Qty>56.000</Qty><QU>Wo</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">H07RN-F 5G35 mm²</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Industrie-Gummischlauchleitungen für mittlere mechanische Beanspruchungen entsprechend</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">DIN-VDE 0282-4.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Eigenschaften und Verwendung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Für den beweglichen Anschluss von Elektrogeräten bei mittleren mechanischen Beanspruchungen in Innenräumen und im Freien. Sie sind verwendbar in gewerblichen und landwirtschaftlichen Betrieben, in explosionsgefährdeten Bereichen nach DIN VDE 065, in feuergefährdeten Betriebsstätten, auf Baustellen nach DIN VDE 0100 Teil 704, im Tagebau und in Steinbrüchen nach DIN VDE 0168.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Sie dürfen auch fest verlegt werden, z.B. in provisorischen Bauten, Wohnbaracken, auf Baggern und Hebezeugen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Technische Daten:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Uo/U: 450/700V</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Mantelfarbe: schwarz</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Gebrauchstemparaturen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">-30° C bis +60° C</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Mindestbiegeradius</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">bei beweglichem Einsatz: 15D (Durchmesser)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">liefern, verlegen und abbauen sowie anschliessen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Mietpreis pro Woche</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">angesetzte Mietdauer 56 Wochen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Länge 20 m</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:481pt;margin-top:0pt;margin-bottom:0pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">H07RN-F 5G35 mm²</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id619" RNoPart="8"><Qty>56.000</Qty><QU>Wo</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">H07RN-F 5G25 mm²</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Industrie-Gummischlauchleitungen für mittlere mechanische Beanspruchungen entsprechend</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">DIN-VDE 0282-4.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Eigenschaften und Verwendung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Für den beweglichen Anschluss von Elektrogeräten bei mittleren mechanischen Beanspruchungen in Innenräumen und im Freien. Sie sind verwendbar in gewerblichen und landwirtschaftlichen Betrieben, in explosionsgefährdeten Bereichen nach DIN VDE 065, in feuergefährdeten Betriebsstätten, auf Baustellen nach DIN VDE 0100 Teil 704, im Tagebau und in Steinbrüchen nach DIN VDE 0168.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Sie dürfen auch fest verlegt werden, z.B. in provisorischen Bauten, Wohnbaracken, auf Baggern und Hebezeugen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Technische Daten:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Uo/U: 450/700V</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Mantelfarbe: schwarz</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Gebrauchstemparaturen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">-30° C bis +60° C</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Mindestbiegeradius</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">bei beweglichem Einsatz: 15D (Durchmesser)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">liefern, verlegen und abbauen sowie anschliessen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Mietpreis pro Woche</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">angesetzte Mietdauer 56 Wochen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Länge 20 m</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:481pt;margin-top:0pt;margin-bottom:0pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">H07RN-F 5G25 mm²</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id620" RNoPart="9"><Provis>WithoutTotal</Provis><Qty>56.000</Qty><QU>Wo</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Verlängerungskabel 5 x 63 A CEE Länge 25 m</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Ausführung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Verlängerungskabel H07RN - F 5G 16 mm²</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">mit Stecker und Kupplung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Stecker- und Kupplungsanschluss mit isolierten Aderendhülsen gefasst</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">die Länge der Aderendhülse entspricht der Anschlusstiefe der Rahmenklemmen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">mit angebrachter Grundbanderole zur Kennzeichnung mit Prüfsiegel des &#x22;Nächster Prüftermin&#x22; nach BGV A3 (VBG 4)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">komplett montiert und geprüft</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Bestückung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">25 m Gummikabel H07RN - F 5G 16 mm²</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 Stück Stecker CEE 5 x 63 A / 6 h</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">glasfaserverstärkter, hochwärmebeständiger Kontaktträger</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Rahmenklemmen und vernickelten Kontakten</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Kabeleinführung mit Verschraubung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">mit Verriegelungsring</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">wasserdicht IP 67 (Referenz - Typ BALS 2189)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 Stück Kupplung CEE 5 x 63 A / 6 h</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">glasfaserverstärkter, hochwärmebeständiger Kontaktträger</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Rahmenklemmen und vernickelten Kontakten</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Kabeleinführung mit Verschraubung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">mit Verschlussdeckel</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">wasserdicht IP 67 (Referenz - Typ BALS 3124)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">liefern, verlegen und abbauen sowie anschliessen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Mietpreis pro Woche</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">angesetzte Mietdauer 56 Wochen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Länge 20 m</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:481pt;margin-top:0pt;margin-bottom:0pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Verlängerungskabel 5 x 63 A CEE Länge 25 m</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id621" RNoPart="10"><Provis>WithoutTotal</Provis><Qty>112.000</Qty><QU>Wo</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Verlängerungskabel 5 x 32 A CEE Länge 25 m</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Ausführung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Verlängerungskabel H07RN - F 5G 6 mm²</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">mit Stecker und Kupplung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Stecker- und Kupplungsanschluss mit isolierten Aderendhülsen gefasst</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">die Länge der Aderendhülse entspricht der Anschlusstiefe der Rahmenklemmen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">mit angebrachter Grundbanderole zur Kennzeichnung mit Prüfsiegel des &#x22;Nächster Prüftermin&#x22; nach BGV A3 (VBG 4)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">komplett montiert und geprüft</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Bestückung:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">25 m Gummikabel H07RN - F 5G 6 mm²</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 Stück Stecker CEE 5 x 32 A / 6 h</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">glasfaserverstärkter, hochwärmebeständiger Kontaktträger</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Rahmenklemmen und vernickelten Kontakten</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Kabeleinführung mit Verschraubung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Kragensteckvorrichtung, isoliergekapselt</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">spritzwassergeschütz IP 44</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">1 Stück Kupplung CEE 5 x 32 A / 6 h</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">glasfaserverstärkter, hochwärmebeständiger Kontaktträger</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Rahmenklemmen und vernickelten Kontakten</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Kabeleinführung mit Verschraubung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Kragensteckvorrichtung, isoliergekapselt</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">spritzwassergeschütz IP 44</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">liefern, verlegen und abbauen sowie anschliessen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Mietpreis pro Woche</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">angesetzte Mietdauer 56 Wochen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Länge 20 m</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">2 Stück = 112 Wochen</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:481pt;margin-top:0pt;margin-bottom:0pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Verlängerungskabel 5 x 32 A CEE Länge 25 m</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy></BoQBody></BoQCtgy><BoQCtgy ID="id622" RNoPart="02"><LblTx><p><span>Baustellenbeleuchtung</span></p></LblTx><BoQBody><BoQCtgy ID="id623" RNoPart="01"><LblTx><p><span>Baustellenbeleuchtung</span></p></LblTx><BoQBody><Itemlist><Remark ID="id624"><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Herstellung einer Baustellenbeleuchtung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Zur Sicherstellung der Verkehrswege innerhalb der Baustelle (Treppenhaus und Flure) ist eine normkonforme Baustellenbeleuchtung incl. Sicherheitsbeleuchtung Nennbetriebsdauer 1 Stunde aufzubauen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Das LED-Lichtsystem muss die Technischen Regeln für Arbeitsstätten ASR A3.4 Pkt. 8 und ASR A2.3 Pkt. 8 für Baustellenbeleuchtungen sowie ASR A3.4/7 Pkt. 4 für Sicherheitsbeleuchtungen erfüllen.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Alle Komponenten müssen die CE-, REACH- und RoHS-Richtlinien erfüllen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Das LED-Lichtsystem ist modular aufgebaut  und kann im Rahmen der zul. max. Systemlänge beliebig mit LED-Lichtbändern erweitert werden. </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Lichtsteuerungen:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Grundsätzliches:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Das System besteht aus min. einer Lichtsteuerung und min. einem LED-Lichtband.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Lichtsteuerungen in verschiedenen Gehäusen und Ausführungen ob Kunststoff-Gehäuse oder Metall-Gehäuse: </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Lichtsteuerung überwacht laufend die Stromversorgung der Lichtbänder und schaltet bei Stromausfall direkt auf das Sicherheits- / Notlichtlicht um.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">In der Lichtsteuerung ist eine einstellbare Zeitschaltuhr und weitere Funktionen integriert.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Die Konfiguration und Bedienung der Funktionen der Lichtsteuerung erfolgt per Web-Oberfläche. (keine APP)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- inkl. Akkumulatoren und Ladegerät</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- Integrierter Lichtschalter fürs Hauptlicht (optional: Schlüsselschalter)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- 4,5 m Gummizuleitung mit Schutzkontaktstecker</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- Eingangsspannung Lichtsteuerung: 220-240 VAC</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- Gerätesicherung der Lichtsteuerung je nach Bauart: 6 A oder 10 A</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:481pt;margin-top:0pt;margin-bottom:0pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Herstellung einer Baustellenbeleuchtung</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Remark><Item ID="id625" RNoPart="1"><Qty>3.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Beleuchtungssystem Baustellenstellenbeleuchtung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Lichtband und Steuergerät mit Anschlußstecker </span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Hauptlicht und Sicherheits-/Notlicht sind in einem Lichtband zusammengefasst.</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Leistungsaufnahme: max. 8 Watt pro Meter Lichtband</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Lichtstrom/m: mind. 1300 Lumen pro Meter Lichtband</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- Leuchtenlichtausbeute (Hauplicht):mind. 162,5 lm/W</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- Energieeffizienzklasse für die Lichtbänder: Klasse C</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- Leistungsaufnahme des Notlichts max. 0,8 W pro Meter Lichtband</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- Notlichterhaltung &#x3e; 1 Std. für Lichtbänder bis max zul. Lichtband-Länge pro Lichtsteuerung</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Lichtband mit verriegelbares und kodiertes Stecker/Kupplung-System inkl. Schutzkappen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- 24/7-Dauerbetrieb möglich</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- Abstrahlwinkel der Beleuchtung: &#x3e; 160°</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- Schutzart IP65</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- Schutzklasse 2</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- Brandeigenschaft des Lichtbands: selbstverlöschend</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- Die Lichtbänder sind silikonfrei (optional + halogenfrei)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- Lichtfarbe 5000 K (ähnlich Tageslicht)</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- Temperaturbereich (Betrieb und Lagerung): -20 °C bis +50 °C</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">- Lebensdauer mind. (mttf) bei TUm = 25 °C: ca. 50.000 Stunden</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Länge pro Stück 30 m</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">liefern und montieren</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:481pt;margin-top:0pt;margin-bottom:0pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Beleuchtungssystem Baustellenstellenbeleuchtung</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item><Item ID="id626" RNoPart="2"><Qty>4.000</Qty><QU>St</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Ummontage der vor beschriebenene Baustellenbeleuchtung während der Bauzeit</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">pauschal</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">incl. Befestigungsmaterial</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:481pt;margin-top:0pt;margin-bottom:0pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Ummontage der vor beschriebenene Baustellenbeleuchtung</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy></BoQBody></BoQCtgy><BoQCtgy ID="id627" RNoPart="03"><LblTx><p><span>Wartung und Instandhaltung Baustelleneinrichtung und Baustellenbeleuchtung</span></p></LblTx><BoQBody><BoQCtgy ID="id628" RNoPart="01"><LblTx><p><span>Wartung und Instandhaltung der Baustelleneinrchtung und Baustellenbeleuchtung</span></p></LblTx><BoQBody><Itemlist><Item ID="id629" RNoPart="1"><Qty>56.000</Qty><QU>Wo</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Wartung und Sicherstellung der Baustellenversorgung und der Baustellenbeleuchtung während der Bauzeit</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Durchführung und Dokumentierung der notwendigen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Messungen und Prüfungen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Sicherstellung der Baustellenversorgung bei Störungen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">durch sofortigen Einsatz und Abhilfemassnahmen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Vorhaltung von ausreichend Sicherungsmaterial an der</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Baustellen zur Beseitigung von Ausfällen</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"/><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">pauschal für die Bauzeit pro Woche abgerechnet</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">(Einheitspreis gilt auch bei Verlängerung der Bauzeit)</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:481pt;margin-top:0pt;margin-bottom:0pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Wartung und Sicherstellung der Baustellenversorgung</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy></BoQBody></BoQCtgy></BoQBody></BoQCtgy><BoQCtgy ID="id630" RNoPart="02"><LblTx><p><span>Stundenlohn</span></p></LblTx><BoQBody><BoQCtgy ID="id631" RNoPart="01"><LblTx><p><span>Stundenlohnarbeiten</span></p></LblTx><BoQBody><Itemlist><Item ID="id632" RNoPart="1"><Qty>10.000</Qty><QU>h</QU><Description><CompleteText><DetailTxt><Text><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Arbeiten gegen Material und Zeitnachweis</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">nach Absprache und einzelner Beauftragung durch die Bauleitung werden berechnet für:</span></p><p style="margin-top:0pt;margin-bottom:0pt;width:284pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Monteur</span></p></Text></DetailTxt><OutlineText><OutlTxt><TextOutlTxt><p style="width:481pt;margin-top:0pt;margin-bottom:0pt;font-size:10pt;"><span style="font-family:Arial;font-size:10pt;">Arbeiten gegen Material und Zeitnachweis</span></p></TextOutlTxt></OutlTxt></OutlineText></CompleteText></Description></Item></Itemlist></BoQBody></BoQCtgy></BoQBody></BoQCtgy></BoQBody></BoQ></Award></GAEB>